Solar panels in an Alberta winter

Cold is good for a solar panel. As the cells cool, voltage rises, and in the same sunlight the panel makes a little more power than its rating. That voltage rise is what a winter array has to be planned around: the Voc on a datasheet is measured at 25 °C, and on the coldest clear morning of the year a string's voltage goes well past it.
Do solar panels work in extreme cold?
Yes, they do. Every panel in our catalogue is rated to operate from −40 to +85 °C. What cuts winter output is light: short days, a low sun and snow on the glass. In late December the noon sun over Calgary sits about 15° above the horizon, against about 39° at the March and September equinoxes.
At what temperature do solar panels become inefficient?
Solar panels lose efficiency as they get hot. A panel's rating is measured with the cells at 25 °C. Above that, output in the same sunlight drops by the panel's temperature coefficient of Pmax, which runs from 0.28% to 0.35% per degree on the panels below, and below 25 °C it rises at the same rate. On a panel at 0.34% per degree, cells at 45 °C on a summer roof give up about 7% of the rating (20 degrees over), and cells at −10 °C on a bright winter day gain about 12% (35 degrees under).
Why does the cold decide how many panels go in a string?
Voc is the voltage a panel makes with nothing connected, and it goes up as the panel gets colder. In a series string the panels' voltages add, and the total has to stay under the maximum PV input of the charge controller or inverter the string feeds. That maximum is a hard limit. If a string goes over it, a Victron SmartSolar 150/100 or 250/100 stops charging and shows error #33. Victron warns that the controller can be damaged, depending on how far over the voltage goes, and that the warranty doesn't cover that damage. The highest string voltage comes when sunlight first reaches panels that are as cold as they get, on a clear winter morning.
How do I work out a panel's voltage in the cold?
The Canadian Electrical Code, Rule 64-202, permits two ways. The first multiplies the panel's rated Voc by 125%, a factor built on a panel temperature of −40 °C, so it needs no temperature for your site. The second starts from the rated Voc and adds the rise the cold causes: the difference between 25 °C and the lowest expected daily minimum at your site, times the panel's temperature coefficient of Voc. For your own panel, check two numbers on its datasheet: Voc and the temperature coefficient of Voc.
Whichever way you use, that figure sets the voltage rating for the cable, disconnects and fuses in those circuits, and it goes on the permanent marking at the disconnect (Rule 64-200). On a dwelling, the ceiling is 600 V DC.
Here are the panels in our catalogue, per panel, both ways:
| Panel | Voc at 25 °C | Voc coefficient | ×125% route | Coefficient route, −40 °C |
|---|---|---|---|---|
| LONGi LR8-54HGBB 500 W | 39.58 V | −0.230 %/°C | 49.5 V | 45.5 V |
| JA Solar JAM66D45-620/LB | 48.50 V | −0.260 %/°C | 60.6 V | 56.7 V |
| LONGi LR7-54HGBB-450M | 39.70 V | −0.230 %/°C | 49.6 V | 45.6 V |
| LONGi LR5-72HPH-545M | 49.65 V | −0.265 %/°C | 62.1 V | 58.2 V |
| LONGi LR5-54HPB-410M | 37.40 V | −0.265 %/°C | 46.8 V | 43.8 V |
| LONGi LR4-60HPB-360M | 40.8 V | −0.270 %/°C | 51.0 V | 48.0 V |
| Canadian Solar CS6R-400MS-HL | 36.8 V | −0.26 %/°C | 46.0 V | 43.0 V |
| Canadian Solar CS6R-395MS-HL | 36.6 V | −0.26 %/°C | 45.8 V | 42.8 V |
The coefficient column uses −40 °C. If your site's lowest daily minimum is warmer, that route gives a lower figure.
How many panels can go in one string?
Divide the controller's maximum PV input by the per-panel figure and round down.
Take the LONGi 500 W on a Victron SmartSolar 250/100 or a MidNite Classic 250, both with a 250 V maximum PV input. On the ×125% route each panel counts as 49.47 V, and five come to 247.4 V. On the coefficient route at −40 °C each counts as 45.50 V, and five come to 227.5 V. Six would be 296.8 V and 273.0 V, over 250 V both ways. So five panels is the limit, and both routes agree.

Sometimes the routes differ by a panel. Take the LONGi 360 W on a 150 V controller, the Classic 150 or the SmartSolar 150/100. The ×125% route allows two, at 102.0 V, because three would be 153.0 V. The coefficient route at −40 °C allows three, at 143.9 V. Both are permitted, but you need to be able to show which one you used, and that figure goes on the marking.
The Voc calculator runs both routes on your own panel and controller and shows the arithmetic.
A string can be too short as well. An MPPT controller charges only while the array's voltage is above the battery's, and the start voltage on its datasheet is the margin it needs. The Victron SmartSolar 150/100 and 250/100 start charging once the array is 5 V above the battery. Panel voltage is lowest on a hot summer day, so check the short end in July, the way you check the long end in January.
What type of solar panel is best for winter use?
The best winter panel is one whose voltage, snow rating and frame fit your site and your controller, and over snow on a ground mount, that's a bifacial panel. Four lines on the datasheet decide it, more than the wattage.
The first is the Voc and its coefficient, against your controller at your coldest temperature. Across these panels the coefficient runs from −0.230 to −0.270 %/°C, so at −40 °C one panel's Voc rises 15% and another's 17.6%.
The second is the snow load. The LONGi and JA panels above are rated 5400 Pa on the front. The Canadian Solar CS6R panels are rated for snow up to 8100 Pa when mounted the way their installation manual describes.
The third is a bifacial panel on a ground mount over snow. The LONGi LR8 and LR7 and the JA 620 also collect light on the back, and snow under the array reflects light onto it. That only helps while the front glass is clear, because a few centimetres of snow on the front lets very little light through. From the back, the LR8 adds 5% to 25% to its 500 W front rating: 525 W to 625 W. On a flush roof mount the back sees little light, so plan on the front rating there. Rear gain shows up as current: at 25% gain the LR8's short-circuit current goes from 15.95 A to 19.93 A while its Voc moves 0.10 V. Check the controller's current limit against the higher figure.
The fourth is the frame your racking takes: 30 mm on the LONGi LR8, LR7 and LR5-54 and the JA 620, and 35 mm on the others.
Not sure your string fits? Bring the panel model, the controller or inverter, and the coldest temperature your site sees to the counter, or call 587-287-9180.
On this page: LONGi LR8-54HGBB 500 W · JA Solar JAM66D45-620/LB · LONGi LR7-54HGBB-450M · LONGi LR5-72HPH-545M · LONGi LR5-54HPB-410M · LONGi LR4-60HPB-360M · Canadian Solar CS6R-400MS-HL and CS6R-395MS-HL · Victron SmartSolar MPPT · MidNite Classic MPPT. Solar panels · MPPT charge controllers.
Every panel and controller figure on this page is from the maker's datasheet, linked on each product page. Code: Canadian Electrical Code, Part 1, Rules 64-200 and 64-202. Sun angles: solar geometry at Calgary's latitude, 51.05° N. Controller behaviour over and under voltage: Victron's SmartSolar MPPT manual.